EJOT Schraubdübel ejotherm STR U 2G 115 mm mit 60-mm-Dübelteller und vormontierter Schraube

Ejot Schraubdübel STR-U-2G

Preis
43,99 € /Pak
(inkl. 19 % MwSt. zzgl. Versand)
Länge (in mm)
Online Lieferung
Geschätzte Lieferung : Samstag, 17 Okt, 2026
9,99 €

9,99 €

12,99 €
Ihr Preis pro
Pak
43,99 €
Stk.
0,44 €
Geben Sie Ihre Menge ein
Pak
Stk.
Ihr berechneter Wert: 43,99 €
inkl. 19 % MwSt. zzgl. Versand
Versandkosten
ab 1
9,99 € / Pak
ab 2
+ 5,00 € / Pak

EJOT screw anchor ejotherm STR U 2G 115 mm for concrete and masonry

The EJOT ejotherm STR U 2G 115 mm screw anchor fastens insulation boards of external thermal insulation composite systems (ETICS) to concrete and masonry. The anchor, with a 60 mm washer and pre-assembled screw, is suitable for use categories A to D with an anchoring depth of 25 mm. In its shortest length, it is designed for insulation thicknesses of 60 to 80 mm and flush mounting, according to the tested data sheets.

📏
8 × 115 mm
Spreading zone Ø 8 mm, plate Ø 60 mm, length 115 mm.
🧱
Categories A–D
This length is for concrete and masonry, not for aerated concrete.
🔩
h ef 25 mm
Anchorage depth 25 mm, borehole depth flush ≥ 35 mm.
🌡️
χ = 0.002 W/K
For flush mounting with EPS plugs.

Who is the STR U 2G 115 mm suitable for?

The dowel is aimed at plasterers and ETICS specialists who dowel thin insulation boards flush with the surface of concrete or masonry.

Areas of application and test points

According to the EJOT data sheet, documentation and system holder information sheet, the following applications and test points apply to this length:

  • 60 mm insulation thickness with 10 to 30 mm adhesive or old plaster layer
  • 80 mm insulation thickness with a 10 mm adhesive layer
  • For 60 mm insulation and 10 mm leveling in hollow building materials, a trial setup is required.
  • Concrete, solid and hollow bricks as well as lightweight aggregate concrete (categories A–D)
  • Not for aerated concrete: Category E requires a 65 mm anchoring depth and longer anchors.
  • Flush mounting, seal dowel shaft with STR plug
  • Can be combined with additional plates VT 90 or SBL 140 plus
  • Determine the dowel length based on the insulation thickness, leveling layer, and anchoring.

Your advantage with thin insulation panels

The short anchoring depth keeps the boreholes in concrete and masonry short, and according to EJOT, the retraction of the plate signals secure anchoring.

Determining the correct dowel length

The length is determined by the thickness of the insulation material, the adhesive or old plaster layer, and the anchoring depth in the substrate.

Application range of the 115 mm length

According to the EJOT application matrix, the 115 mm length is suitable for 60 mm insulation with up to 30 mm leveling layer or for 80 mm insulation with 10 mm adhesive.

Recessed mounting only from 135 mm

The recessed mounting according to the STR principle requires a greater drilling depth; according to the system holder information sheet, it applies from a dowel length of 135 mm, for example with the STR U 2G in 135 mm .

Assembly and limits

Flush-mounted anchors are sealed with the EJOT STR plug . The specified loads are characteristic manufacturer values; according to EJOT, a safety factor of 3 should be applied in Germany, but the ETA and ETICS verification remain authoritative.

Product features at a glance

✓ Polyethylene dowel sleeve with pre-assembled steel screw
✓ Plate diameter 60 mm
✓ Anchorage depth 25 mm in categories A–D
✓ TX30 screw drive
✓ Placement control by retracting the plate
✓ χ-value 0.002 W/K with flush mounting
✓ European Technical Assessment ETA-04/0023
✓ Can be combined with additional plates VT 90 and SBL 140 plus

Technical data: EJOT ejotherm STR U 2G 115 mm

The information is taken from the EJOT data sheet, the ETA-04/0023 and system holder documents; the current ETA and the proof of the ETICS apply to the design.

Manufacturer and typeEJOT ejotherm STR U 2G 115
Article numbersManufacturer: 8719115400; Keuck: 12510
Sales unit1 pack of 100 pieces
DimensionsLength 115 mm; Spreading zone Ø 8 mm; Plate Ø 60 mm
Insulation thickness (EJOT matrix, category A–D)60 mm with a 10–30 mm leveling layer; 80 mm with a 10 mm leveling layer
Mounting type of this lengthFlush-mounted; recessed installation according to system holder from 135 mm dowel length
Drill hole depth and anchoring (flush, A–D)h 2 ≥ 35 mm; h ef ≥ 25 mm
Screw driveTORX TX30
Point-specific heat transfer χ0.002 W/K flush with surface using EPS plug
Characteristic loads (manufacturer's specifications)Concrete ≥ C12/15, Mz, KS, KSL: 1.5 kN; Hlz: 1.2 kN; LAC: 0.9kN; V, HbL: 0.6 kN
Materials according to ETAPolyethylene dowel sleeve (new product); pre-assembled steel screw
EvidenceETA-04/0023 dated June 5, 2023 (EAD 330196-01-0604); Z-21.2-1769