The EJOT ejotherm STR U 2G 115 mm screw anchor fastens insulation boards of external thermal insulation composite systems (ETICS) to concrete and masonry. The anchor, with a 60 mm washer and pre-assembled screw, is suitable for use categories A to D with an anchoring depth of 25 mm. In its shortest length, it is designed for insulation thicknesses of 60 to 80 mm and flush mounting, according to the tested data sheets.
The dowel is aimed at plasterers and ETICS specialists who dowel thin insulation boards flush with the surface of concrete or masonry.
According to the EJOT data sheet, documentation and system holder information sheet, the following applications and test points apply to this length:
The short anchoring depth keeps the boreholes in concrete and masonry short, and according to EJOT, the retraction of the plate signals secure anchoring.
The length is determined by the thickness of the insulation material, the adhesive or old plaster layer, and the anchoring depth in the substrate.
According to the EJOT application matrix, the 115 mm length is suitable for 60 mm insulation with up to 30 mm leveling layer or for 80 mm insulation with 10 mm adhesive.
The recessed mounting according to the STR principle requires a greater drilling depth; according to the system holder information sheet, it applies from a dowel length of 135 mm, for example with the STR U 2G in 135 mm .
Flush-mounted anchors are sealed with the EJOT STR plug . The specified loads are characteristic manufacturer values; according to EJOT, a safety factor of 3 should be applied in Germany, but the ETA and ETICS verification remain authoritative.
The information is taken from the EJOT data sheet, the ETA-04/0023 and system holder documents; the current ETA and the proof of the ETICS apply to the design.
| Manufacturer and type | EJOT ejotherm STR U 2G 115 |
| Article numbers | Manufacturer: 8719115400; Keuck: 12510 |
| Sales unit | 1 pack of 100 pieces |
| Dimensions | Length 115 mm; Spreading zone Ø 8 mm; Plate Ø 60 mm |
| Insulation thickness (EJOT matrix, category A–D) | 60 mm with a 10–30 mm leveling layer; 80 mm with a 10 mm leveling layer |
| Mounting type of this length | Flush-mounted; recessed installation according to system holder from 135 mm dowel length |
| Drill hole depth and anchoring (flush, A–D) | h 2 ≥ 35 mm; h ef ≥ 25 mm |
| Screw drive | TORX TX30 |
| Point-specific heat transfer χ | 0.002 W/K flush with surface using EPS plug |
| Characteristic loads (manufacturer's specifications) | Concrete ≥ C12/15, Mz, KS, KSL: 1.5 kN; Hlz: 1.2 kN; LAC: 0.9kN; V, HbL: 0.6 kN |
| Materials according to ETA | Polyethylene dowel sleeve (new product); pre-assembled steel screw |
| Evidence | ETA-04/0023 dated June 5, 2023 (EAD 330196-01-0604); Z-21.2-1769 |